Answer:This and many other products are now available for order online and pickup at the Power Equipment Direct warehouse in Bolingbrook, Illinois or at a Ferguson Supply location near you.
How Do I Update My Pickup Location?
Answer:The nearest pickup location within a 50-mile radius is automatically chosen when you enter the site. To change your pickup location and see availability for other nearby locations, click the "Change Pickup Location" link on the product page or in the cart.
How Do I Place a Local Pickup Order?
Answer:Eligible items will have the Local Pickup option available both on the product page and in the cart. Select this option for all items you wish to pick up. Please note that Local Pickup can only be scheduled online at this time.
When Can Items Be Picked Up?
Answer:Items are usually ready for pickup the same day the online order is placed, but this will depend on order volume and time of day. When your order is ready, you will receive an email including specific pickup instructions. Orders that have not been picked up within two business days may be cancelled. You should opt to have your items shipped if you are not able to pick them up promptly.
Who Can Pick Up My Order?
Answer:You will be prompted to enter the name, mobile phone, and email address of the person who will be picking up the order during checkout. We will use this information to ensure the order is picked up by an authorized individual.
Why Can't I Select Local Pickup for Some Items?
Answer:Not all items are available at all locations, so pickup availability will vary based on the selected store. Additionally, some items ship directly from our manufacturer partners and are not available for pickup. You can use the "Change Pickup Location" link to check for availability at nearby Local Pickup locations.
Why Can't I Select Shipping for Some Items?
Answer:Due to packaging, shipping costs, and other factors, some items cannot be shipped and are offered exclusively through Local Pickup.
Which Payment Methods Are Accepted?
Answer:Credit/debit cards, Apple Pay, Google Pay, PayPal, and financing are accepted for Local Pickup orders.
Hover to zoom
1 Of 5
Red Lion RL-SPRK200 - 76 GPM 2 HP Self-Priming Cast Iron Sprinkler Pump
Expert Recommended AccessoriesSelected by Jim, our Expert
Required Accessories9
These accessories are required to properly setup/install this product.
Optional Accessories10
Features
Inlet Size
2 Inch
Style
Sprinkler
GPM
76 Gallons
2 HP Lawn Sprinkler Pump
For use in underground or above ground lawn sprinkling systems
Also for garden irrigation, boosting household water pressure
Can be used for recirculation of large volumes of water
Heavy-Duty Cast Iron Construction w/ Thermoplastic Impeller
Designed for years of service and reliability
230 Volt Heavy-Duty Motor
Allows for simple connection to existing power source
Self-Priming Design
After initial fill, no additional priming required
Engineered Pump Housing & Hydraulics
For high performance, efficiency and quiet operation
Additional Specs
2" NPT Intake / 1-1/2" NPT Discharge
10.9 A @ 230 V
2-Year Warranty
Specifications
97102001
General Information
Product Category
Water Pump
Motor
Voltage
230 Volt
Running Amps
10.9
Pump
Gallons Per Minute
76 Gallons
Inlet Diameter
2 Inch
Outlet Diameter
1-1/2 Inch
Self Priming
Yes
Pump Housing Drain
Yes
Housing Material
Cast Iron
Impeller Material
Plastic
Suction Head
25 Feet
Maximum PSI
49
Submersible
No
Engine
Horsepower
2 hp
Overview
Product Category
Water Pump
Weight
64 Pounds
Consumer Warranty
2 Years
Product Length
19.9 Inches
Product Width
9.25 Inches
Product Height
12 Inches
UPC
010121001411
Additional Model Numbers
RL-SPRK200, 97102001
Reviews
(98)
Red Lion 97102001 Reviews & Ratings
Customer Photos and Videos
Product Q&A
(2)
Product QuestionsAnswered by Jim, the Water Pump Expert
Is this pump self-priming? Does it need a foot valve?
Bret
from Colorado
February 24, 2020
Answer
Most pumps, including this Red Lion pump, are self-priming, but they will require you to prime the pump by filling the priming port and pump housing with water upon initial installation, to force any air out and allow for the impeller to start sucking water. Any air pockets left in the lines or the pump will cause the pump to become air-bound. An air-bound pump will not operate properly until the air is removed and replaced by water. As long as a check or foot valve is installed on the suction pipe and you never lose suction, you should not need to re-prime the pump.
Was this answer helpful?
Yes
10
No
3
Do you know which terminals the wires from the 230 vac connect to, if it matters?
Charlene M.
from Utah
August 12, 2019
Answer
All wiring instructions for that pump are located on pages 3 & 4 of the PUMP MANUAL. If you still have problems, please reach out to Red Lion tech support at 888-956-0000 for further assistance.
Was this answer helpful?
Yes
2
No
2